SPECIFICATIONS
Brand Name: NoEnName_Null
Origin: Mainland China
Hign-concerned Chemical: None
DIY Supplies: ELECTRICAL
Type: ultrasound scanner
Certification: CE
Model Number: Vet Ultrasound Scanner
Size: Veterinary Ultrasound
Style: Ultrasound Machine
Output Type: ultrasound machine
Place of Origin: Guangdong, China
Model Number: SY-W002
Properties: Diagnosis & Injection
Product name: Animal Hemodialysis Machine
Size: 870*410*1330mm
Weight: 35kg
Voltage: 220V/110V
Frequency: <500VA
Blood flow: 1-250ml/min
Accuracy: ±10%
Venous pressure: -10kPa-101KPA
Dear customer, I am in charge of this series of products and I serve as the company manager. You can contact me to obtain more discounts and other new product information. I can arrange training and use of the products for you to ensure that you can use them quickly and efficiently. This is my contact information. Please contact me before placing an order to obtain the correct price, which includes details of transportation and shipping costs. This is my business card information,
Manager Wu WeChat: 18966023528
WhatsApp:+86 18966023528
mailbox:15367315926@163.com
If you are still satisfied with our product and want to get more discounts and product information, please add my contact information so that I can send more detailed product information,This is my business card information,
Manager Wu WeChat: 18966023528
WhatsApp:+86 18966023528
mailbox:15367315926@163.com
SUNNYMED Reliable Quality Affordable Price
SY-W002 Vet Dialysis Machine Animals Kidney Hemodialysis Instrument Veterinary Hemodialysis Machine

Why this model?
Features
* Direct use of the prepared dialysis fluid ensures 100% accurate dialysis fluid concentration, simpler, more convenient and
safer.
* The entire hemodialysis treatment process is carried out with disposable consumables and operates completely airtight, with no possibility of external contamination.
* The unique high-flow convection plus diffusion dialysis mode provides high dialysis efficiency. The dialysis time is usually completed within 2-3 hours.
* The weighing method is used to control the amount of ultrafiltration with an accuracy of ±5%, which is of great importance for small animals.
* The flow of dialysate in and out can be adjusted simply and efficiently, providing precise control of ultrafiltration.
* The use of high throughput dialysis, i.e, the rapid removal of creatinine, urea nitrogen, but also remove the pathogenic
molecular weight of toxic substances, inflammatory substances, in acute renal failure has the effect of both the symptoms and the root cause of the treatment.
* It is designed in accordance with the small blood volume in vitro, the volume of dialyzer plus hemodialysis tube can be
controlled at 30ml. Hemodialysis can be easily carried out on animals from 3 to 50 kg.
* LCD display, touch key, easy parameter setting, no need to be equipped with a special water purifier, easy to operate.
* Small size, light weight, easy to move, and dialysis fluid can be moved at will even after it has been prepared, so that
hemodialysis treatment can be carried out in different rooms and locations and it can also go out for on-site treatment.
* Direct use of the prepared dialysis fluid ensures 100% accurate dialysis fluid concentration, simpler, more convenient and
safer.
* The entire hemodialysis treatment process is carried out with disposable consumables and operates completely airtight, with no possibility of external contamination.
* The unique high-flow convection plus diffusion dialysis mode provides high dialysis efficiency. The dialysis time is usually completed within 2-3 hours.
* The weighing method is used to control the amount of ultrafiltration with an accuracy of ±5%, which is of great importance for small animals.
* The flow of dialysate in and out can be adjusted simply and efficiently, providing precise control of ultrafiltration.
* The use of high throughput dialysis, i.e, the rapid removal of creatinine, urea nitrogen, but also remove the pathogenic
molecular weight of toxic substances, inflammatory substances, in acute renal failure has the effect of both the symptoms and the root cause of the treatment.
* It is designed in accordance with the small blood volume in vitro, the volume of dialyzer plus hemodialysis tube can be
controlled at 30ml. Hemodialysis can be easily carried out on animals from 3 to 50 kg.
* LCD display, touch key, easy parameter setting, no need to be equipped with a special water purifier, easy to operate.
* Small size, light weight, easy to move, and dialysis fluid can be moved at will even after it has been prepared, so that
hemodialysis treatment can be carried out in different rooms and locations and it can also go out for on-site treatment.





Main Functions
|
Hemodialysis; Blood Perfusion (Poisoning Rescue); Simple Ultrafiltration (Dehydration); Liver Ascites Recovery
|
Blood Pump
|
Blood pump flow range: 0.1mL/min~250mL/min
|
Step value: 1mL/min
|
|
Error: ±10%
|
|
Liquid Pump
|
Liquid pump flow range: 2mL/min to 600mL/min
|
Step value: 1mL/min
|
|
Error: ±10%
|
|
Venous Pressure Monitoring
|
Venous pressure range: -13kPa to 66.7kPa (-100mmHg to 800mmHg), resolution: 1mmHg
|
Venous pressure indication accuracy: ±1.3kPa (±10mmHg)
|
|
Adjustable high and low limits for venous pressure alarms, with an alarm action error of ±1.3kPa (±10mmHg)
|
|
Dialysis Hydraulic Monitoring
|
Dialysis hydraulic pressure range: -13kPa to 66.7kPa (-100mmHg to 800mmHg), resolution:1mmHg
|
Dialysis hydraulic pressure indication accuracy: ±1.3kPa (±10mmHg)
|
|
Dialysis hydraulic alarm high limit adjustable, with alarm action error ±1.3kPa (±10mmHg)
|
|
Stable state of continuous operation during 4 hours
|
Fluctuation in dialysate flow rate is of 5%
|
Fluctuation in blood flow rate is of 5%
|
|
Pressure Control
|
The pressure monitoring equipment should have an intravenous pressure and dialysis pressure monitoring system
|
Alarm Action
|
When intravenous pressure monitoring system is alarmed, the equipment shall have the corresponding alarm action: triggering an audible and visual alarm
|
Air Protection System
|
A protection system to prevent safety-related risks to patients due to air entering the body. When air enters the pipeline, the protection system is activated. An audible and visual alarm is emitted and the blood pump is stopped at the same time, blocking the venous circuit and preventing air bubbles from entering the body.
|
FAQ
1. How to buy?
A. Contact our sale directly!
B. Place the order online.
B. Place the order online.

2. How to pay?
A. Trade assurance
B. Credit Card
C. Paypal in Alibaba
B. Credit Card
C. Paypal in Alibaba
D.T/T(Bank Transfer)
E. Western union
F. L/C
E. Western union
F. L/C
Return policy
3. How long to wait for the order?
A. Ready stock within 24 hours
B. OEM need 2-7 working days
C. Safety delivery:special one-to-one inspection service before arranging the delivery
B. OEM need 2-7 working days
C. Safety delivery:special one-to-one inspection service before arranging the delivery

4. How to use our product?
A. Video tutorial: including installation, operation, repairing and maintenance
B. Real Time Online Video Call at your convenience: Pre-sales and after-sales online video training
B. Real Time Online Video Call at your convenience: Pre-sales and after-sales online video training
5. Warranty and after-sale service
A.12-60 months
B.After-sales service: Reply within 8 hours
B.After-sales service: Reply within 8 hours
Product to be used together
Why Choose Us
We are based in Guangdong, China, starting from 2014. Products are sold to South America, Southeast Asia, North America, and Africa, ect. .

Manager Wu WeChat: 18966023528
WhatsApp:+86 18966023528
mailbox:15367315926@163.com
Share